HDR-7100P
Digital Refractor
Phoropter that provides fast and precise testing with dual cross-cylinder lenses
- Accurate all eye examinations
- Assisting with various types of global standard examinations
- Provided a customized optometry
MENU
Explore Details
Accurate all eye examinations
By providing a 30% faster dual cross cylinder, astigmatic testing, and cylinder axis examination can be rapidly & precisely measured. All the presbyopia examination and myopia examinations can be measured on the center of the HDR-7100P window.





Assisting with various types of global standard examinations
Apply to the 18 of visual acuity tests and 26 vision test charts of monocular and binocular. The position of the chart and visual target can be randomly changed due to the diverse types of charts used worldwide.
Provided a customized optometry
With the adjustment of the monocular PD, it is available to measure as per the customer The HDR can check whether the patient has the right posture because the headrest sensor is embedded


Video
Reviews
Huvitz MEMBERS
Specifications
1. Measurement Range
Spherical Lens
-29.00 ~ +26.75D (Regular)
-19.00 ~ +16.75D (During XC or prism tests)
(0.12/0.25/0.5/1/2/3/4D 단위)
Cylinder Lens
0.00 ~ ±8.75D (0.25/0.5/1/2/3D increments)
Cylinder Axis
0 ˚~ 180 ˚ (1/ 5/ 15 ˚ increments)
PD
48 ~ 80mm (0.5/1mm increments)
Near PD : 50 ~ 74mm
Near Working Distance : 35 ~ 70cm
Rotary Prism Lens
0 ~ 20△ (0.1/0.2/0.5/1/2△ 단위)
Cross Cylinder
±0.25D
±0.50D
±0.25D prism split lens (Dual Cross Cylinder)
Retinoscopic Lens
+1.5D, +2.0D (Measurement Distance 67cm, 50cm)
2. Auxiliary Lenses
Occluding Aperture
-
Pinhole Lens
ø2mm
Maddox Rod
Right Eye (Red, Horizontal), Left eye (Red, Vertical)
Red/Green Filter
Right Eye (Red), Left Eye (Green)
Polarizing Filter
Right Eye (135 ̊, 45 ̊), Left Eye (45 ̊, 135 ̊)
Split(dissociation) Prism
Right Eye (6△ BU)
Left Eye (10△ BI : up to 5△ complement)
PD Check Lens
-
Fixed XC Lens
±0.50D, 축 고정 90°
Visual Field
40° (VD > 12mm)
3. Hardware Specification
Digital Refractor
368.7 (W) X 106.4 (D) X 345.5 (H)mm, 4.2kg
Operation Panel
216.4 (W) X 246.1 (D) X 230.2(H)mm, 1.9kg (including internal printer)
Junction Box
71 (W) X 240 (D) X 251(H)mm, 1.9kg
Rated voltage
· Digital Refractor : 18V 1.5A
· Operation Panel : 18V 2.5A
· Junction Box : 100~240 V~ 1.2~0.6A, 50/60Hz
Current
100~240 V~ 1.5~0.6A 50/60Hz
WIFI
Optional
Medical device Classification
B Type Applied Part
* Specification and design are subject to change without notice.
FAQ
Q. What are the core features of the HDR-7100P?
A. The HDR-7100P is a phoropter equipped with dual cross-cylinder lenses, enabling astigmatic axis and power testing to be performed approximately 30% faster and more precisely than before. Accurate measurements are maintained through the lens center even during presbyopia and near-vision testing. It also supports prisms adjustable up to 20Δ in 0.1Δ increments and automatic occlusion, allowing stable heterophoria and binocular vision testing. In addition, it supports a wide range of international standard examination methods, including visual acuity tests and monocular and binocular correction tests, making it highly flexible for diverse examination environments.
Q. Who is the HDR-7100P suitable for?
A. The HDR-7100P is well suited for optical shops, optometry rooms, and ophthalmic clinics that require fast and accurate examinations for astigmatism, addition power, and binocular vision. With dual cross-cylinder lenses and broad support for examination methods, it enables stable testing regardless of the user’s level of experience. User-oriented features such as PD adjustment and a forehead rest sensor make it suitable for patients of various age groups and a wide range of examination settings.
Q. What types of examination charts are provided by the HDR-7100P?
A. The HDR-7100P supports a wide variety of globally used chart types and examination methods, offering 18 visual acuity tests and 26 monocular and binocular correction test charts. Chart layouts and optotypes can be randomized according to the situation, minimizing memorization effects and enabling more accurate examinations.
Q. What is the automatic occlusion function of the HDR-7100P?
A. The automatic occlusion function of the HDR-7100P automatically covers the fellow eye when examining one eye. This allows the examiner to switch occlusion states quickly and accurately using only the console buttons, without the need for manual occluders. The function ensures a smooth examination flow, is particularly useful for precise comparison of visual acuity between both eyes, and helps reduce overall examination time.
Q. What convenience features are available when using the HDR-7100P?
A. The HDR-7100P provides a comfortable, patient-specific examination environment through independent left and right monocular PD adjustment and a forehead rest sensor. Monocular PD adjustment allows precise alignment with each patient’s interpupillary distance, while the forehead rest sensor automatically detects patient posture during the exam, helping maintain a stable and consistent examination position.