  • HDR-9000 PC type OP software V1.1.12019-05-09 열기
    v1.1.1

    Load Last function
    able to restore the last deleted data

    change date display format
    ex) “18/01/30”  “Jan/30/2018”

    data transmission format bug fix
    HDR-mate data

    LM, RK button and touch button function bug fix

    change masking function
    when the chart device setting is HDC-7000 or HDC-9000
    the point masking position after row masking moves to the right

    change fog values while the program function
    the fog values in the program are removed next program step

    stabilize bluetooth serial connection
    add delay to wait connection

    fix bug PD auto set in user settings

    additional program edit function
    add "others" tab
    even if the random chart option is on, do not display random chart in the edit page

    custom edit
    even if the random chart option is on, do not display random chart in the edit page

    add jog dial function setting
    settings --> test environment [2] jog button function
    settings --> test environment [2] jog button random [on][off]
    the above setting allows random chart function to press jog dial button

    add axis display option
    settings --> test environment [2] horizontal axis setting [0][180]
    axis 0 to 180

    canon RK-F2 protocol support
    only F2 protocol

    PC Hub connection

    add function keys(bottom of the screen) in the age setting dialog page

    21 test function bug fix

    PC type OP function
    able to adjust CC lens by pressing keyboard
    spacebar key

    SCA data selection can be done with up and down arrow keys

    lens values can be adjust with right and left arrow keys

    change windows focus policy
    toolbar and mainwindow now activate or deactivate at the same time

    system tray icon
    admin config --> system setting [3]

    change font display with windows dpi setting

    single instance application

    change auto export function

    other huvitz devices can be connected with serial port of the PC without junction box
    fileHDR-9000_installer_1.1.1.exe.zip Download
    fileHDR Quick guide_HDR-9000_PC SW OP.pdf Download
  • HDR-9000 PC type OP software V1.1.02017-09-19 열기
    -Random Chart
    This function can be used when the random setting [ON].
    For temperal usage press Alt button and set RANDOM ON in the function key button.
    Press Alt + Set button or wheel click to randomize the VA chart.
    Support only HDC-9000PF/N after version 1.2.1.

    - Touch Masking
    Now, masking operations can be done by clicking the area of the current chart characters.
    Support only HDC-9000PF/N after version 1.2.1.

    - Control Contrast of the chart
    Press Alt button then the Function key buttons below the test view
    is changed to CONTRAST+, CONTRAST-
    Support only HDC-9000PF/N after version 1.2.1.

    - Log
    HDR-9000 Operation Panel writes the log files of important processes, communications and button pressed.
    Each log files can be exported to USB or specific folder selected.
    fileHDR-9000_installer_1.1.0.zip Download
    fileHDR Quick guide_HDR-9000_PC SW OP.pdf Download
  • HDR-9000 PC type OP software V1.0.102017-05-17 열기
    -FIX: Error when prism notation changing from BDBU/BIBO -> r/theta

    -FIX: the problem that PD value is not set when reveiving data from RK/LM

    -FIX: VA data display problem when the chart type is set to M-type

    -FIX: Correct the VA masking behavior in Program Edit/Custom Edit
    Correct fog value to be changed correctly

    -FIX: fog_val, fog_rg setting item function modification

    -FIX: modify input fusion, input stereo, input coincidence [YES][NO] item behavior during the setting동작 수정
    fileHDR-9000_installer_1.0.10.exe Download
    fileHDR Quick guide_HDR-9000_PC SW OP.pdf Download
  • HDR-9000 PC type OP software V1.0.92016-11-30 열기
    Modifications

    - ADD: chart device support for chinese
    -> CDC-9000, CCP-9000

    - FIX: the action changed when loading the data from LM and RK
    -> Preview without charging lens of transmitted data value and press OK button or SET button to charge lens
    -> Fixed to rotate selected item when mouse wheel is input while moving data list in Load menu

    - FIX: Receiving Kerato data normally
    -> Corrected to display the Kerato Data value of receive data

    - ADD: able to recieve the RK and LM data via CAN Box working with HDR-7000 junction box
    fileHDR-9000_installer_1.0.9.zip Download
    fileHDR Quick guide_HDR-9000_PC SW OP.pdf Download
  • HDR-9000 PC type OP Software V1.0.82016-06-13 열기
    HDR-9000
    - CHANGE: modification VA's size of one of the CDC-4000 C type Number chart.

    Only PC type OP Software
    - ADD: support various Export function
    -> add HDR-Mate Protocol V1.0, V1.1, V1.2(Engineer Mode setting)
    - FIX: incorrect Import function.
    - ADD: when th PC Software starting up, send reset message to Refractor body.
    - ADD: add item on Engineer Mode setting.
    -> Delete File After Import
    -> Auto Export
    -> Export File Name
    -> User Defined Export File Name
    -> Auto Import Path
    fileHDR-9000_installer_1.0.8.zip Download
    fileHDR Quick guide_HDR-9000_PC SW OP.pdf Download